Operation examples (continued)

<MOTION DETECTION

SETTINGS>￿

>>SELECTION CAMERA

NUMBER￿

1

DETECTION MASK SETTING￿

 

SENSITIVITY

HIGH••<<<LOW￿

MOTION THRESHOLD

 

5￿

TEST MODE￿

 

OFF￿

MD LOCK OUT TIME

 

￿

4)<TIMER PROGRAM SETTINGS> screen setting ( see pages 44 to 46)

SELECTED PATTERN: “P3”

ALARM REC DURATION: “5M”

<TIMER PROGRAM SETTINGS>￿

>>SELECTED

PATTERN

P3-SET￿

HOLIDAY SETTING￿

 

REC MODE A￿

 

REC MODE B￿

 

REC MODE C￿

 

REC MODE D￿

5M

ALARM REC DURATION

5)<ALARM SETTING C> screen setting ( see page

All the cameras (“ 1 ” to “ 4 ”):

TRIGGER: “MD/EXT”

• EMR: Set all the cameras (“ 1 ” to “ 4 ”).

 

 

 

 

<ALARM

SETTING C>￿

TRIGGER￿

ALARM

RECORD CAMERA

>>1

1 ---

MD/EXT￿

2

- 2--

MD/EXT￿

3

-- 3-

MD/EXT￿

4

--- 4

MD/EXT￿

EMR￿

1 2 3 4

 

 

￿

TYPE

ALARM CH￿

ALARM

￿

 

 

 

￿

CLEAR:BACK

 

 

6)<RECORD SETTING C> screen setting ( see page

All the cameras (“ 1 ” to “ 4 ”):

PPS, GRADE, A-PPS, A-GRADE: Set the desired interval and picture quality for each camera.

ALARM TYPE: “ALARM CH”

PRE ALARM REC: Set the desired pre-alarm recording time.

 

 

 

 

 

 

<RECORD SETTING

C>￿

A-GRADE￿

NO

PPS

GRADE

A-PPS

>>1

3.125P

STD

3.125P

HIGH￿

2

3.125P

STD

3.125P

HIGH￿

3

3.125P

STD

3.125P

HIGH￿

4

3.125P

STD

3.125P

HIGH￿

￿

 

 

 

ALARM CH￿

ALARM TYPE

REC

 

PRE ALARM

 

MEDIUM￿

￿

 

 

CLEAR:BACK￿

<ESTD REC>

 

 

D H

M

 

7)<ALARM SETTING D> screen setting ( see page

Camera numbers “ 1 ” and “ 3 ” only:

TRIGGER: “MD/EXT”

 

 

 

 

<ALARM

SETTING D>￿

TRIGGER￿

ALARM

RECORD CAMERA

>>1

1 ---

MD/EXT￿

2

- 2 --

EXT￿

3

--3-

MD/EXT￿

4

--- 4

EXT￿

EMR￿

1 2 3 4

 

 

￿

TYPE

ALARM CH￿

ALARM

￿

 

 

 

￿

CLEAR:BACK

 

 

8)<RECORD SETTING D> screen setting ( see page

Camera numbers “ 1 ” and “ 3 ” only:

PPS, GRADE, A-PPS, A-GRADE: Set the desired interval and picture quality for each camera.

Other camera:

PPS, GRADE: “- - - - - -”

ALARM TYPE: “ALARM CH”

PRE ALARM REC: Set the desired pre-alarm recording

time.

<RECORD SETTING

D>￿

NO

PPS

GRADE

A-PPS A-GRADE￿

>>1

6.25P

SUPER

------ STD￿

2

------

STD

------ STD￿

36.25P SUPER ------ STD￿

4------ STD ------ STD￿

￿

ALARM CH￿

ALARM TYPE

PRE ALARM REC

MEDIUM￿

￿

CLEAR:BACK￿

<ESTD REC>

D H M

9)<TIMER PROGRAM> screen setting ( see page 44)

PROGRAM NO.1 : “SPL,” “08:00,” “15:00,” “C,” “ON.”

PROGRAM NO.2 : “SPL,” “15:00,” “08:00,” “D,” “ON.”

PROGRAM NO.3 : “SAT,” “08:00,” “08:00,” “D,” “ON.”

PROGRAM NO.4 : “SUN,” “08:00,” “08:00,” “D,” “ON.”

SPL: “MON - FRI”

 

 

 

 

 

 

<TIMER PROGRAM>

 

P3￿

>>1

DW

START END MODE

MD￿

SPL

08:00 15:00 C

ON￿

2

SPL

15:00•08:00 D

ON￿

3

SAT

08:00•08:00 D

ON￿

4

SUN

08:00•08:00 D

ON￿

5

---

--:-- --

:-- ----

---￿

6

---

--:-- --

:-- ----

---￿

7

---

--:-- --

:-- ----

---￿

8

---

--:-- --

:-- ----

---￿

￿

 

MON-FRI

 

 

 

SPL

 

 

 

When completed with all the settings above and after clearing the menu screen, press both the TIMER ON/ OFF buttons. The unit switches to the timer programming mode.

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

60