Other convenient functions (continued)

PARTITION/PARTITION SIZE

This item is used to set an independent partition in HDD as sub-device capacity for alarm recording. In the MAIN HDD, normal recording and alarm recording are stored.

1.Turn ON the MAIN switch on the rear panel, and wait until the ACCESS indicator turns off. Make sure that the POWER button on the front panel is turned off. While holding down the JOG button, press the POWER button on the front panel.

The <INITIALIZATION> screen apprears.

2. Press the JOG , buttons to move the cursor to “HDD SETTING” and then press the ENTER button.

• The background of the setting item turns red and flashes.

3. Press the JOG ,buttons to display “PARTITION” and then press the ENTER button.

The setting item is determined and flashing stops.

The “PARTITION SIZE” setting appears in the <INITIALIZATION> screen.

<INITIALIZATION>￿

PARTITION￿

>>HDD SETTING

PARTITION SIZE

10%￿

BOOT UP DELAY

30S￿

￿

 

POWER OFF￿

 

INITIALIZATION￿

 

￿

 

￿

 

￿

 

ALL DATA WILL BE ERASED￿

WHEN PROCEED INITIALIZATION

4.Press the JOG , buttons to move the cursor to “PARTITION SIZE” and then press the ENTER button.

Setting of “PARTITION SIZE” (default: 10%)

10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90%

The area for normal recording is referred to as “MAIN,” and area for alarm recording (PARTITION area) is referred to as “SUB.”

The area of MAIN HDD set in “PARTITION” is displayed with the percentage (%) and the recordable time of that storage area is displayed in “<ESTD REC>.”

ALARM TYPE

ALARM CH￿

PRE ALARM REC

 

OFF￿

￿

CLEAR:BACK￿

<ESTD REC>

D H M

%

 

5.Press the JOG , buttons to display the desired device capacity and then press the ENTER button.

The setting item is detemined.

6.Select “INITIALIZATION” by pressing the JOG , buttons and then press the ENTER button.

The setting is determined, and initialization is executed.

Be sure that all the data in the HDD is erased when executing initialization.

While PARTITION is performed, “25P” cannot be set for PPS or A-PPS, and “SUPER” cannot be set for GRADE or A-GRADE in <RECORD SETTING> screen.

To exit <INITIALIZATION> screen without setting “HDD SETTING,” select “POWER OFF.”

Points to notice concerning PARTITION

Playback, search, information display, REMAIN HDD, MODE OUT, CALL OUT, and data erase functions are performed independently for “MAIN” and “SUB.”

When “HDD REPEAT REC SUB” is set to “OFF,” and all the memory in SUB HDD is used, the recording stops. Switch “HDD REPEAT REC SUB” to “ON” or erase data in SUB HDD to restart recording.

When setting “ALARM CH” and an alarm signal is input to a camera number that is not set for normal recording, pre-alarm recording may not be performed.

While PARTITION is performed, the number registered in alarm list is not cleared even when clearing the data of HDD MAIN or SUB. When an alarm is input after clearing the HDD, that alarm is numbered as the next one of the last input number.

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

70