■Basic manual recording
Normal recording using manual operation is described below. Before you start recording, check the settings of “HDD REPEAT REC MAIN” and “HDD REPEAT REC SUB” in the <HDD SETTINGS> screen (see page 47), and then set the recording settings.
Settings here are for normal recording only. For timer recording, settings must be made on the <TIMER PROGRAM SETTINGS> screen (
see page 44).
♦Setting the recording interval and recording picture quality for normal recording
To perform normal recording, “PPS” and “GRADE” must be set for each camera.
| Number of |
|
|
|
| ||
| operational | # 1 | # 2 | # 3 | # 4 | ||
PPS |
| cameras | |||||
|
|
|
|
| |||
|
|
| 25P | 12.5P | 8.33P | 6.25P | |
SHORT | 12.5P | 6.25P | 4.165P | 3.125P | |||
|
|
| 8.333P | 4.167P | 2.777P | 2.083P | |
|
|
| 6.25P | 3.125P | 2.083P | 1.563P | |
|
|
| 5P | 2.5P | 1.666P | 1.25P | |
Recording | |||||||
4.167P | 2.083P | 1.388P | 1.042P | ||||
| interval |
|
|
|
| ||
| 3.125P | 1.563P | 1.041P | 0.781P | |||
|
|
| 2.5P | 1.25P | 0.833P | 0.625P | |
|
|
| 1P | 0.5P | 0.333P | 0.25P | |
|
|
| |||||
| LONG | 0.5P | 0.25P | 0.167P | 0.125P | ||
|
|
| 0.25P | 0.125P | 0.083P | 0.063P | |
|
|
|
|
|
|
| |
|
|
| 0.125P | 0.063P | 0.042P | 0.031P | |
|
|
|
|
|
|
|
Setting of “PPS” (default: “3.125P”)
“6.25P,” “3.125P,” “2.083P,” “1.563P,” “1.25P,” “1.042P,” “0.781P,” “0.625P,” “0.25P,” “0.125P,” “0.063P,” “0.031P,” “- - - - -
“- - - - -
Available recording intervals vary depending on the number of cameras operating or ALARM RECORDING settings (
see page 41). See the chart above for the displaying interval.
Setting of “GRADE” (default: “STD”)
“SUPER,” “HIGH,” “STD”(STANDARD), “BASIC,” “LONG”
Example: Setting “PPS” of camera number “ 1 ” to “1.25P” and “GRADE” to “HIGH” for normal recording.
1.Press the SET UP button to display the <SETTINGS> screen.
2.Press the JOG ,
buttons to move the cursor to “RECORD SETTINGS” and then press the ENTER button.
•The <RECORD SETTINGS> screen appears.
<RECORD | SETTINGS> |
|
>>ALARM | SETTING |
|
RECORD | SETTING | 5S |
ALARM | REC DURATION |
3.Press the JOG ,
buttons to move the cursor to “RECORD SETTING” and then press the ENTER button.
•The <RECORD SETTING> screen appears.
|
|
|
|
|
|
<RECORD SETTING> | |||||
NO | PPS | GRADE | |||
>>1 | 3.125P | STD | 3.125P | STD | |
2 | 3.125P | STD | 3.125P | STD | |
3 | 3.125P | STD | 3.125P | STD | |
4 | 3.125P | STD | 3.125P | STD | |
|
|
| ALARM CH | ||
ALARM TYPE | REC |
| |||
PRE ALARM |
| OFF | |||
|
| CLEAR:BACK | |||
<ESTD REC> |
| ||||
| D H | M |
|
CAUTION: For <ESTD REC>,
see “Continuous recording time table” on page 77.
About <ESTD REC>
•The remaining recordable time is displayed as <ESTD REC> depending on the “PPS” and “GRADE” settings. (This time is not change when changing the alarm recording settings.) For the details concerning the estimated recordable time, see page 77.
4.Check that the cursor is positioned at “ 1 ” and then press the ENTER button.
•The setting item of “PPS” is highlighted.
<RECORD SETTING> | ||||
NO | PPS | GRADE | ||
1 | 3.125P | STD | 3.125P | STD |
2 | 3.125P | STD | 3.125P | STD |
3 | 3.125P | STD | 3.125P | STD |
4 | 3.125P | STD | 3.125P | STD |
|
|
|
|
5.Press the ENTER button again.
•The background of the setting item turns red and flashes.
<RECORD SETTING> | ||||
NO | PPS | GRADE | ||
1 | 3.125P | STD | 3.125P | STD |
2 | 3.125P | STD | 3.125P | STD |
3 | 3.125P | STD | 3.125P | STD |
4 | 3.125P | STD | 3.125P | STD |
|
|
|
|
The menu screen is not cleared even when pressing the SET UP button while the setting item is flashing.
6.Press the JOG ,
buttons to select “1.25P” and then press the ENTER button.
•Setting item is determined and flashing stops.
<RECORD SETTING> | |||||
NO | PPS | GRADE | |||
1 | 1.25P |
| STD | 3.125P | STD |
2 | 3.125P |
| STD | 3.125P | STD |
3 | 3.125P | STD | 3.125P | STD | |
4 | 3.125P | STD | 3.125P | STD | |
|
|
|
|
|
ENGLISH
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Basic Operations
25