Basic manual recording

Normal recording using manual operation is described below. Before you start recording, check the settings of “HDD REPEAT REC MAIN” and “HDD REPEAT REC SUB” in the <HDD SETTINGS> screen (see page 47), and then set the recording settings.

Settings here are for normal recording only. For timer recording, settings must be made on the <TIMER PROGRAM SETTINGS> screen ( see page 44).

Setting the recording interval and recording picture quality for normal recording

To perform normal recording, “PPS” and “GRADE” must be set for each camera.

 

Number of

 

 

 

 

 

operational

# 1

# 2

# 3

# 4

PPS

 

cameras

 

 

 

 

 

 

 

 

25P

12.5P

8.33P

6.25P

SHORT

12.5P

6.25P

4.165P

3.125P

 

 

 

8.333P

4.167P

2.777P

2.083P

 

 

 

6.25P

3.125P

2.083P

1.563P

 

 

 

5P

2.5P

1.666P

1.25P

Recording

4.167P

2.083P

1.388P

1.042P

 

interval

 

 

 

 

 

3.125P

1.563P

1.041P

0.781P

 

 

 

2.5P

1.25P

0.833P

0.625P

 

 

 

1P

0.5P

0.333P

0.25P

 

 

 

 

LONG

0.5P

0.25P

0.167P

0.125P

 

 

 

0.25P

0.125P

0.083P

0.063P

 

 

 

 

 

 

 

 

 

 

0.125P

0.063P

0.042P

0.031P

 

 

 

 

 

 

 

Setting of “PPS” (default: “3.125P”)

“6.25P,” “3.125P,” “2.083P,” “1.563P,” “1.25P,” “1.042P,” “0.781P,” “0.625P,” “0.25P,” “0.125P,” “0.063P,” “0.031P,” “- - - - - -”

“- - - - - -”: Recording is not performed with camera set to this item.

Available recording intervals vary depending on the number of cameras operating or ALARM RECORDING settings ( see page 41). See the chart above for the displaying interval.

Setting of “GRADE” (default: “STD”)

“SUPER,” “HIGH,” “STD”(STANDARD), “BASIC,” “LONG”

Example: Setting “PPS” of camera number “ 1 ” to “1.25P” and “GRADE” to “HIGH” for normal recording.

1.Press the SET UP button to display the <SETTINGS> screen.

2.Press the JOG , buttons to move the cursor to “RECORD SETTINGS” and then press the ENTER button.

The <RECORD SETTINGS> screen appears.

<RECORD

SETTINGS>￿

 

>>ALARM

SETTING￿

 

RECORD

SETTING￿

5S￿

ALARM

REC DURATION

￿

3.Press the JOG , buttons to move the cursor to “RECORD SETTING” and then press the ENTER button.

The <RECORD SETTING> screen appears.

 

 

 

 

 

 

<RECORD SETTING>￿

A-GRADE￿

NO

PPS

GRADE A-PPS

>>1

3.125P

STD

3.125P

STD￿

2

3.125P

STD

3.125P

STD￿

3

3.125P

STD

3.125P

STD￿

4

3.125P

STD

3.125P

STD￿

￿

 

 

 

ALARM CH￿

ALARM TYPE

REC

 

PRE ALARM

 

OFF￿

￿

 

 

CLEAR:BACK￿

<ESTD REC>

 

 

D H

M

 

CAUTION: For <ESTD REC>,

see “Continuous recording time table” on page 77.

About <ESTD REC>

The remaining recordable time is displayed as <ESTD REC> depending on the “PPS” and “GRADE” settings. (This time is not change when changing the alarm recording settings.) For the details concerning the estimated recordable time, see page 77.

4.Check that the cursor is positioned at “ 1 ” and then press the ENTER button.

The setting item of “PPS” is highlighted.

<RECORD SETTING>￿

A-GRADE￿

NO

PPS

GRADE A-PPS

1

3.125P

STD

3.125P

STD￿

2

3.125P

STD

3.125P

STD￿

3

3.125P

STD

3.125P

STD￿

4

3.125P

STD

3.125P

STD￿

￿

 

 

 

 

5.Press the ENTER button again.

The background of the setting item turns red and flashes.

<RECORD SETTING>￿

A-GRADE￿

NO

PPS

GRADE

A-PPS

1

3.125P

STD

3.125P

STD￿

2

3.125P

STD

3.125P

STD￿

3

3.125P

STD

3.125P

STD￿

4

3.125P

STD

3.125P

STD￿

￿

 

 

 

 

The menu screen is not cleared even when pressing the SET UP button while the setting item is flashing.

6.Press the JOG , buttons to select “1.25P” and then press the ENTER button.

Setting item is determined and flashing stops.

<RECORD SETTING>￿

A-GRADE￿

NO

PPS

GRADE A-PPS

1

1.25P

 

STD

3.125P

STD￿

2

3.125P

 

STD

3.125P

STD￿

3

3.125P

STD

3.125P

STD￿

4

3.125P

STD

3.125P

STD￿

￿

 

 

 

 

 

ENGLISH

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Basic Operations

25