<SERVICE PORT SETTING>￿

•00080￿

>>WEB

USER ACCESS

53705￿

SUPER USER

53706￿

LIVE USER1

53707￿

LIVE USER2

53708￿

LIVE USER3

53709￿

LIVE USER4

53710

2.Press the JOG , buttons to select the desired setting and then press the ENTER button.

The first figure of the port number is highlighted.

3.Press the JOG , buttons to highlight the number to be changed and then press the ENTER button.

The background of the selected number turns red and flashes.

4.Press the JOG , buttons to display the desired port number and then press the ENTER button.

The setting item is determined and stops flashing.

To display the cursor, press the CLEAR button.

When you change “WEB” setting, the “ • ” displayed on the left of the port number turns its color from green to red.

5.To change other settings, repeat steps 2 to 4.

6.Return to the <ETHERNET> screen by pressing the CLEAR button and then press the SET UP button to exit if no changes are made.

7.When settings are changed, press the SET UP button. (In this case, the CLEAR button does not function.) The unit is reset and turned on again automatically.

• ALARM NOTIFICATION SETTING

This menu is used to transmit warning signals or signals of status change such as a short circuit of a rear terminal to the connected PC.

The specified software is required. Please refer to the instruction manual of the software.

Issuing of reports to broadcast addresses is not supported.

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } <COMMUNICATION PORT SETTING> } Select “ALARM NOTIFICATION SETTING” in the <ETHERNET> screen.

The <ALARM NOTIFICATION SETTING> screen appears.

<ALARM NOTIFICATION SETTING>￿

NO

IP ADDRESS

TARGET OWN￿

>>1

000.000.000.000•55111 01111￿

2

000.000.000.000•55111 01112￿

3

000.000.000.000•55111 01113￿

4

000.000.000.000•55111 01114￿

5

000.000.000.000•55111 01115￿

￿

 

OFF￿

WARNING

ALARM SENS

OFF￿

REC MODE

OFF￿

RETRY TIME

10S￿

￿

2.(When setting the IP ADDRESS or port setting number, etc. of the connected PC • • • )

Press the JOG , buttons to select the desired setting number and then press the ENTER button.

The first figure of the port number is highlighted.

3.Press the JOG , buttons to highlight the figure of IP ADDRESS, TARGET PORT, and OWN PORT to be changed and then press the ENTER button.

The background of the selected number turns red and flashes.

4.Press the JOG , buttons to display the desired number and then press the ENTER button.

The setting item is determined and flashing stops.

To display the cursor, press the CLEAR button.

When TARGET PORT number is set to 00000 to 01023, the “ • ” situated on the left of the value turns red from green, and in case of 01024 to 49151, it turns yellow.

5.To change other setting number, repeat steps 2 to 4.

6.(When setting the contents to transmit to the connected PC • • • )

Press the JOG , buttons to select the desired setting and press the ENTER button.

The background of the setting item turns red and flashes.

Setting of “WARNING” (default: “OFF”)

“ON”: Transmits warning message to the connected PC. E-mail is sent to address displayed on “USER ADDRESS” of the <E-MAIL ADDRESS> screen.

OFF”: Does not transmit the warning message.

Setting of “ALARM SENS” (default: “OFF”)

“ON”: Transmits the state to the connected PC when the ALARM IN terminal is short circuited. E-mail is sent to address displayed on “USER ADDRESS” of the <E-MAIL ADDRESS> screen.

OFF”: Does not transmit the state.

Setting of “REC MODE” (default: “OFF”)

“ON”: Transmits the state of normal recording or alarm recording, etc. to the connected PC. E-mail is sent to address displayed on “USER ADDRESS” of the <E-MAIL ADDRESS> screen.

OFF: Does not transmit the state.

Setting of “RETRY TIME” (default: “10S”) 1S, 2S, • • • •, 10S, • • • • • • 59S, 60S

7.Press the JOG , buttons to display the desired setting and then press the ENTER button.

The setting item is determined and flashing stops.

8.Return to the <ETHERNET> screen by pressing the CLEAR button and then press the SET UP button to exit if no changes are made.

9.When settings are changed, press the SET UP button. (In this case, the CLEAR button does not function.) The unit is reset and turned on again automatically.

When you change “WARNING,” “ALARM SENS,” “REC MODE,” or “RETRY TIME” only, the CLEAR button is also available.

ENGLISH

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations

53