♦MAIN HDD DATA CLEAR/SUB HDD DATA CLEAR This menu is used to erase the data recorded on the MAIN HDD or SUB HDD.
<MAIN HDD DATA CLEAR>
PUSH WARNING RESET KEY
FOR 3 SECOND TO CLEAR
<SUB HDD DATA CLEAR>
PUSH WARNING RESET KEY
FOR 3 SECOND TO CLEAR
When executing “MAIN HDD DATA CLEAR” while mirroring function is in operation, all the data will be erased.
Data cannot be erased while the HDD is accessed such as recording/playback.
When executing HDD CLEAR while the
When the MAIN switch on the rear panel is set to OFF or when a menu is displayed, SIMPLE LOCK and PASSWORD LOCK do not function.
♦SIMPLE LOCK
When SIMPLE LOCK is turned on, buttons other than the SPLIT/SINGLE, +,
To activate simple lock • • •
1.Press and hold the LOCK button for more than 3 seconds while both the MAIN switch is set to ON.
•The lock turns on. “LOCK” displays on the screen when “DUPLEX MODE DISPLAY” in <TIME DATE/DISPLAY SETTINGS> screen is set to “TOP” or “BOTTOM.”
To release simple lock • • •
1.Press and hold the LOCK button for more than 3 seconds.
•The lock is released.
♦PASSWORD LOCK
There are 2 types of PASSWORD LOCK, “OPERATION CONTROL” and “HDD DATA CLEAR.”
“OPERATION CONTROL” has 3 levels of lock (level 1 to 3). “HDD DATA CLEAR” (level 4) locks the settings of “MAIN HDD DATA CLEAR” and “SUB HDD DATA CLEAR.”
<Using “OPERATION CONTROL” of PASSWORD LOCK (level 1 to 3)>
1)Input the PASSWORD of levels 1 to 3.
2)Set the PASSWORD LOCK.
•The PASSWORD LOCK of level 1 turns on.
ENGLISH
1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } Select “MAIN HDD DATA CLEAR” or “SUB HDD DATA CLEAR” in the <INFORMATION/SERVICE> screen. Press the ENTER button.
•“PUSH WARNING RESET KEY FOR 3 SECOND TO CLEAR” appears on the bottom of the screen.
•To cancel erasing, press the CLEAR button.
When executing “MAIN HDD DATA CLEAR” or “SUB HDD DATA CLEAR” while the PASSWORD of level 4 has been registered and the lock is turned on, <UNLOCK PASSWORD> screen appears. In this case, release the lock first.
2.Press the WARNING RESET button for more than 3 seconds.
•“CLEARING ...” appears on the screen.
3.Press the CLEAR button or the SET UP button.
■PASSWORD
This unit is equipped with 2 lock functions:
SIMPLE LOCK: Does not require to enter a password when unlocking.
PASSWORD LOCK: Requires to enter a password when unlocking.
•When the password for unlocking is not set, lock function executes in SIMPLE LOCK.
•When the password for unlocking is set, lock function executes in PASSWORD LOCK.
When the MAIN switch on the rear panel is set to ON, SIMPLE LOCK/PASSWORD LOCK setting can be made even with the POWER button on the front panel set to OFF.
When the PASSWORD LOCK of level 1 turns on, operations for all the functions are locked.
3)Unlock the PASSWORD LOCK of level 1.
•The PASSWORD LOCK of level 2 turns on.
When the PASSWORD LOCK of level 2 turns on, only the SPLIT/SINGLE, +,
4)Unlock the PASSWORD LOCK of level 2.
•The PASSWORD LOCK of level 3 turns on.
When the PASSWORD LOCK of level 3 turns on, the SET UP button and ALARM INTERRUPT button are locked.
5)Unlock the PASSWORD LOCK of level 3.
•The PASSWORD LOCK of all the levels are released.
You can operate all the functions.
In the levels 1 and 2, press and hold the LOCK button to display the <UNLOCK PASSWORD> screen, and then input the PASSWORD to release the lock.
In the level 3, press the SET UP button to display the <UNLOCK PASSWORD> screen and then input the
PASSWORD.
When the MAIN switch on the rear panel is set to ON, the PASSWORD can be registered, set, and cancelled even when the POWER button on the front panel is turned OFF.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
55