Replacing CVX 600 Components

Replacing Modules and Filler Panels

Replacing Other Service Modules

The MACs and DAC-SMs provide the processing capabilities for the rear-installed LTMs. When you remove an online service module, the CVX 600 redirects processing to an adjacent secondary module that uses the same LTM. These service modules can occupy chassis slots 1 to 4.

Replacement Procedure

The procedure for replacing these service modules is the same as the procedure for replacing the SCC-SM.

Reference

See the CVX Multi-Service Access Switch Product Description for information on where to position the modules.

Caution: Do not install E1-DAC and DS1-DAC cards in the same chassis. Because the CVX switch synchronizes to one external clock, a CVX switch that contains both E1-DAC and DS1-DAC cards will not function properly, and is not supported.