CVX 600 Hardware Installation Guide

SCC-LTM/-RLTM Interfaces

SCC-LTM/-RLTM Interfaces

The following table lists the interfaces on the SCC-LTM and SCC-RLTM:

Interface

Description

 

 

Console

• One DB-9 RS-232 serial port

 

 

 

HSSI

One port

(SCC-HSSI-RLTM)

50-pin connector

 

• Status LED on the SCC-SM for the SCC-HSSI-RLTM

 

 

10/100BASE-TX

• Switched IEEE 802.3 with autosensing capabilities

 

RJ-45 connectors

 

• MIPS R5000, 64 bit, 180 MHz

 

MDI-X

 

Full-duplex operation

 

• Status LEDs on the SCC-SM

 

 

Alarms

• Up to six independent alarm signals: three audible, three

 

 

visual

 

Gold-clad silver-alloy contacts

 

Note: The contacts on the terminal block are rated at 30 VAC

 

and have a maximum current rating of 1 A. The circuit

 

connecting the alarms must meet the safety extra-low voltage

 

(SELV) requirements. The wires connecting the alarms must

 

be the appropriate gauge for alarm devices.

 

 

Clock

The following applies to all DAC LTMs with an external clock

 

port:

 

• The external clock cicuitry contains a standard T1/

 

 

E1 LIU device with receive TIP/RING terminated at

 

 

120 ohms (incoming twisted pair).

 

• T1 clock rate = 1.544 MHz

 

• E1 clock rate = 2.048 MHz

 

• Port is hardwired for Bipolar Mode only.

 

• Port uses B8ZS/HDB3 encoding/decoding.

 

The external clock port meets or exceeds specifications in

 

ANSI T1.403 and T1.408; ITU I.431, G.703, G.736,

 

G.775 and G.823; ETSI 300-166 and 300-233; and

 

AT&T Pub 62411.

 

 

 

A-18

296-1011-202 Rel. 5.0, Doc. Rev. 02.01

Page 160
Image 160
Nortel Networks CVX 600 manual SCC-LTM/-RLTM Interfaces, Interface Description