CVX 600 Hardware Installation Guide

Connecting Network Cables

Connecting to E1 Interfaces

The E1-DAC-LTM provides 12 or 24 E1 ports and one port for connecting to an external clocking device. To connect E1 cables to the E1 ports, and to connect the

E1-DAC-LTM to an external clocking device, follow this step:

Step

Action

 

1

Plug the connectors into the receptacles.

 

 

Clock

 

Connect to the

12

 

11

 

 

10

 

external clocking

 

 

device (optional).

 

9

8

7

6

5

4

3

12 E1 ports

E

2 1

Connect to the external clocking device (optional).

Clock

 

 

 

 

12

21

20

 

 

 

 

24 E1 ports

 

9

 

17

 

8

16

 

 

 

 

 

 

5

4

 

 

 

 

Connect to the telephone network.

CVX-0243A

Note: Using shielded cabling is an electromagnetic interference (EMI) requirement for CVX 600 E1 network configurations.

Note: For UK installations using 75 ohm E1 coax, a balun is needed to connect to the 120 ohm impedance of the CVX switch. Nortel does not recommend a specific balun panel for this application.

2-10

296-1011-202 Rel. 5.0, Doc. Rev. 02.01

Page 54
Image 54
Nortel Networks CVX 600 manual Connecting to E1 Interfaces