Page 81
Image 81

Chassis Connections

Connecting Equipment to the Console Port

Connecting a Modem

If you need remote dial-in access to the command line interface (CLI), you can connect a modem (AT or Hayes compatible) to the CVX 600 using the DB-9 to DB-25 modem cable.

To connect a modem to the CVX 600, follow these steps:

Step

Action

 

 

 

 

1

Turn on the modem, then configure it using the parameters listed

 

below.

 

 

For instructions, see the documentation for the modem.

 

 

 

 

Modem Parameter

Value/State

 

 

 

 

Baud rate

56 Kb/s (or less)

 

 

 

 

Auto answer

Set to n rings with DTR active.

 

 

(The value n must be greater than

 

 

0. If the value is 0, Auto answer is

 

 

disabled.)

 

 

 

 

Clear to send (CTS) signal

Always on

 

 

 

 

Data terminal ready (DTR) signal

DTR signal fail-disconnect

 

 

enabled. Return to command

 

 

mode; Auto answer is disabled.

 

 

 

 

Data carrier detect (DCD) signal

DCD signal on while carrier

 

 

present. (The CVX 1800 uses the

 

 

DCD signal to detect a modem

 

 

disconnect.)

 

 

 

 

Local character echo

Off

 

 

 

 

Supervisory functions

Off

 

 

 

 

Data set ready (DSR) signal

On

 

 

 

2

Turn off the modem.

 

 

 

3

Remove the console cable from the console port.

 

 

 

 

 

(continued)