The CVX 600 is powered by an AC or DC power source. Use the information in this section to plan for AC or DC power.

AC Power Requirements

The installation site must meet the following AC power requirements:

Input voltage: 85 to 264 VAC

Proximity to wall receptacle: within 6 ft (1.8 m)

Line frequency: 47 to 63 Hz

Fuses: internal (not accessible)

DC Power Requirements

The installation site must meet the following DC power requirements:

Nominal -48 VDC; range: -37 VDC to -56 VDC; 0.5 kW maximum

DC current: 10 A at -48 VDC

Caution: Input DC voltage must not exceed -72 VDC.