Chassis Connections

Connecting Alarms

Alarm Types

The following table lists specific alarm types, severity, and possible causes:

Alarm Type

Severity

Description

 

 

 

T1 Alarm

Critical

An alarm condition has been detected on the

 

 

specified T1 line, or the signal on the T1 line has

 

 

been lost.

 

 

 

T3 Alarm

Critical

An alarm condition has been detected on the

 

 

specified T3 line, or the signal on the T3 line has

 

 

been lost.

 

 

 

HSSI Port Down

Critical

The HSSI port has failed to initialize.

 

 

 

Ethernet Port

Major

The Ethernet port has failed to initialize.

Down

 

 

 

 

 

Fan Down

Major

The cooling fans have stopped.

 

 

 

Power Down

Major

The external power source has dropped.

 

 

 

SCC Failover

Major

The primary SCC has failed, and the secondary SCC

 

 

has resumed operation. CVXView generates this

 

 

alarm. Although the raising trap is generated on the

 

 

CVX 600, it does not recognize this as an alarm

 

 

condition. This alarm must be cleared manually on

 

 

CVXView (Clear Alarms button).

 

 

 

Link Down

Minor

The sending protocol entity recognizes a failure in

 

 

one of the communication links represented in the

 

 

agent’s configuration.

 

 

 

Slot Down

Minor

Communication has been lost between the indicated

 

 

slot and the SCC.

 

 

 

Sonet/SDH

Major

Transitions are not detected on incoming signals,

Loss of Signal

 

therefore, a loss of signal is declared.

 

 

 

Sonet/SDH

Major

An OOF/SEF defect has persisted for a period of 3

Loss of Frame

 

milliseconds, therefore, a loss of frame is declared.

 

 

 

Sonet/SDH C2

Minor

The C2 field value in the received frame does not

Mismatch

 

match the configured value in the SigLabelExpect

 

 

attribute.

 

 

 

Sonet/SDH S1

Minor

The specified STM-1 is in S1 New Alarm. The S1

New Event

 

field in the received frame contains a new value.

 

 

 

 

 

(continued)

296-1011-202 Rel. 5.0, Doc. Rev. 02.01

2-3

Page 47
Image 47
Nortel Networks CVX 600 manual Alarm Types, Alarm Type Severity Description