Chassis Connections

Checking the LEDs

Optical DAC

The following figure shows the LEDs on the Optical DAC-SM:

 

Good

 

 

 

 

 

 

 

 

 

 

STM1/OC32x

 

 

Redun

LOFLOS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pwr

Fail

A1

 

B1

A2

B2

CVX-0144B

LEDs on the Optical DAC-SM

The following table describes the LEDs on the Optical DAC-SM:

LED

State

Meaning

 

 

 

 

 

Power

Off

Power off

 

 

On (green)

Power on

 

 

 

 

 

Good

On (green)

Successful system boot: no errors

 

 

 

detected

 

 

Off

No power: failure detected or on standby

 

 

Flashing green

Code loading during system boot

 

 

 

 

 

Fail

Off

No power

 

 

On (red)

Failure detected

 

 

 

 

 

Redun

Off

No power or no redundancy

 

 

On (green)

A working redundant configuration

 

 

 

 

 

LOF

Off

Normal

 

 

On (orange)

The SONET/SDH framing bytes for A1 or

 

 

 

A2 are wrong or corrupted.

 

 

 

 

 

LOS

Off

Normal

 

 

On (orange)

The designated port has a loss of carrier

 

 

 

condition, due to a faulty connection with

 

 

 

an SC connector on the receive side or a

 

 

 

physical break in the fiber.

 

 

 

 

 

 

 

 

 

Note: There are no LEDs on the Optical DAC-LTMs.

296-1011-202 Rel. 5.0, Doc. Rev. 02.01

2-51

Page 95
Image 95
Nortel Networks CVX 600 manual Following figure shows the LEDs on the Optical DAC-SM