5.2 Cooling

Enough free space should be left around the frequency converter to ensure sufficient air circulation and cooling. The required dimensions for free space are in the table below.

If several units are mounted above each other the required free space equals C + D (see figure below). Moreover, the outlet air used for cooling by the lower unit must be directed away from the inlet air to be used by the upper unit.

 

Type

 

Dimensions

 

 

 

 

A

A2

B

 

C

D

 

0003—0012 NX_5

20

 

20

 

100

50

 

0016—0031 NX_5

20

 

20

 

120

60

 

0038—0061 NX_5

30

 

20

 

160

80

 

0072—0105 NX_5

80

 

80

 

300

100

 

0140—0205 NX_5

20

200

80

 

300

200

 

 

 

(150*)

 

 

 

 

 

 

 

 

 

 

 

 

Table 5-6. Mounting space dimensions

A= clearance around the freq. converter (see also A2 and B)

A2 = clearance needed on either side of the frequency converter for fan change (without disconneting the motor cables)

*= min. clearance for fan change (without disconnecting the

motor cables) between two frequency converters

B= distance from one frequency converter to another or distance to cabinet wall

C= free space above the frequency converter

D= free space underneath the frequency converter

A

A2

C

B

B

 

 

 

A

A2

D

NK5_2

 

 

Figure 5-6. Installation space

 

 

 

 

Type

Cooling air required [m3/h)

 

0004—0015 NX_2

 

 

0003—0012 NX_5

70

 

0005—0019 NX_6

 

 

0018—0032 NX_2

 

 

0016—0031 NX_5

190

 

0022—0062 NX_6

 

 

0048—0078 NX_2

 

 

0038—0061 NX_5

425

 

0085 NX_6

 

 

0092—0150 NX_2

425

 

0072—0105 NX_5

 

 

 

0140—0205 NX_5

650

 

0100—0122 NX_6

 

 

Table 5-7. Required cooling air.

 