7

Control keypad

75(86)

If the user wants the parameters of the new application to be automatically uploaded to the keypad this will have to be done for the parameters of the new application once on page 6.5.1 as instructed. Otherwise the panel will always ask for the permission to upload the parameters.

Note: Parameters saved in the parameter settings on page S6.5.3 will be deleted when applications are changed If transfer of the parameters from one application to another is required, they must be uploaded first to the keypad.

7.3.6.6Parameter comparison

In the Parameter comparison submenu (S6.6), the actual parameter values to the values of thecustomised parameter sets and those loaded to the control keypad can be compared.

The comparison is performed by pushing the right arrow menu button when in the Parameter comparison submenu. The actual parameter values are first compared to those of the customised parameter Set1. If no differences are detected a '0' is displayed on the lowermost line. But if any of the parameter values differ from those of the Set1 the number of the deviations is displayed together with symbol P (e.g. P1#P5 = five deviating values). By pressing the right arrow menu button once again it is possible to enter the pages where both the actual value and the value it was compared to can be seen. In this display, the value on the Description line (in the middle) is the default value and the one on the value line (lowermost) is the edited value. Furthermore, it is possible to also edit the actual value with the Browser buttons in the edit mode that you can reach by pushing the right arrow menu button once again.

RE ADY

RE ADY

 

 

I/Oterm

I/Oter m

 

 

ParamComparison

Set1

 

 

C1"C3

0

 

 

 

OR

 

 

 

READY

 

READY

 

I/Oterm

 

I/Oterm

 

Set1

P2.1.2= 50.0

 

P1"P6

 

20.0 Hz

 

READY

 

 

 

I/Oterm

 

EDIT VALUE

 

 

 

 

P2.1.2= 50.0

 

 

 

20.0 Hz

enter

CONFIRM CHANGE

 

 

 

Figure 7-21. Parameter comparison