Section
4
Installing the Fuel System
!DANGER
!WARNING
4.1Before You Begin
For efficient and safe operation of the Oasis™ Heating Module, follow all recommendations for properly installing the fuel system. Any deviations from these must be approved in advance by ITR.
Use only diesel fuel, furnace oil, or stove oil in the Oasis™ Heating Module. DO NOT USE GASOLINE, CRANKCASE OIL, OR ANY OIL CONTAINING GASOLINE.
Keep fuel lines away from any heat source above 100°F (38°C).
Keep gasoline and any equipment that uses gasoline away from the Oasis™ Heating Module location. The Oasis™ Heating Module is not rated for use in an explosive environment.
Never share the fuel supply to the Oasis™ Heating Module with any other
4.2Fuel System Installation
The fuel pump in the Oasis™ Heating Module has a maximum flow capacity of 25 GAL/Hr and a maximum pressure of 11.5 psi. A 10 micron fuel filter is recommended. Select a fuel filter based on these requirements.
Recommendations for Installation
The Oasis™ Heating Module’s fuel connection is accessed from the top of the heater. The fuel inlet, labelled, is located on the top right of the Oasis™ Heating Module and consists of a 1/8” NPT threaded female fitting. The fuel return, labelled, is located next to the fuel inlet and consists of a 1/8” NPT threaded female fitting. Minimum
International Thermal Research |