Section 2, Mounting the Oasis™ Heating Module

Combustion air must be drawn from an outside source and cannot contain any combustible gases.

Oasis™ Heating Module must be mounted in an area that provides unrestricted access to the front panel. Allow space for connection to the fuel and coolant lines, as well as the power and exhaust connections. (Minimum of 10” top clearance - top exhaust version; minimum of 6” top clearance - bottom exhaust version; 0” clearance to all other Oasis™ Heating Module surfaces). Allow 1” clearance on the sides for attaching the mounting brackets.

Mount the unit with the front panel side facing out and accessible. Facing out simplifies installation and maintenance.

Oasis™ Heating Module must be mounted horizontal and level using eight, 1/4” through bolts and 1” diameter fender washers, lock washers and nuts.

!DANGER

!WARNING

Figure 2-1: Module Dimensions

Oasis™ Heating Module must not be installed or operated in any compartment with flammable gases.

If the Oasis™ Heating Module is going to be mounted in the engine compartment, check for adequate ventilation. When the engine is running this area could be under a negative pressure. Make sure the air-intake and exhaust hoses have no leaks and are well fastened to the heater, muffler and thru-hull fitting. Assembly

International Thermal Research