Section 6, Wiring the Electrical System

6.3120 VAC

NOTICE

The Oasis™ Heating Module is equipped with two 1500 watt, 120 VAC immersion elements (other voltages and frequencies are available). The connections for the electrical supply are on the top left side of the Oasis™ Heating Module, under a cover, labeled AC power.

The power wires for the AC immersion elements are three 14 gauge stranded copper leads that use standard AC color code (black-hot, white–neutral, green-ground). These are to be connected using standard 120 VAC electrical connectors and terminals.

There are two sets of power wires, one set with black heat shrink (primary) and one set without heat shrink (secondary). Each individual set must be connected to a separate AC circuit breaker. The primary set is connected to the single AC element side of the Oasis™ Heating Module. The secondary set of wires is connected to the other AC element. If only one AC circuit breaker is available, you must connect to the primary wire set only. Once the connections are completed, the wires are to be inserted back into their compartment and the cover secured.

The ground wire (green) is shared between the two connections.

Do not operate the electric immersion elements until water is added to the Oasis™ Heating Module and Distribution Module, and all trapped air has been removed.

6.4Remote Operating Panel Cable

One connection on top of the Oasis™ Heating Module is a multi- wire, sheathed cable with a 9 pin connector. This connects to a matching connector on a short adapter cable. The other side of the cable has a 10 pin connector that connects to a 25’ remote cord. This remote cord then plugs directly into the Remote Operating Panel. Refer to Figure 6-1: System Wiring.

If the Distribution Module is used, refer to Section 9, Installing the Distribution Module.

6-2

The Oasis™ Heating Module