Section 8, Operating the Heating Module

Turn the engine preheat switch on the Remote Operating Panel to the ON position with the burner or AC switch on. The engine preheat pump and coolant pump will be activated once the Oasis™ Heating Module is in its set operating temperature range. The engine will start to be preheated by the Oasis™ Heating Module.

Note: An engine preheat pump does not come supplied with the Distribution Module. The power and ground for the pump is available from the Distribution Module.

Engine Heat Used for Domestic Water or Space Heating

Start the vehicle engine and let it come up to the normal operating temperature. Turn the burner switch on the Remote Operating Panel to the ON position. The Oasis™ Heating Module will come up to the set operating temperature range and will cycle OFF. The heat from the vehicle engine will be transferred from the engine to the domestic water and space heating loop.

8.9Functions of the Remote Operating Panel

The Oasis Heating Module’s Remote Operating Panel, Figure 8-3: Remote Operating Panel, contains one ON/OFF burner switch, one triple position AC element switch, one ON/OFF engine heat switch to control the optional engine pre- heat pumps, and four LED’s indicating Burner activation, AC element activation (CH50 used in tandem with Distribution Module), module fault, and zone fault.

Figure 8-3 Remote Operating Panel

International Thermal Research