Section 8, Operating the Heating Module
Burner Switch (Primary Heat Source)
•The burner switch on the remote panel controls the ON/OFF of the diesel burner. The Burner LED will turn on when the diesel burner has been activated.
AC Element Switch (Secondary Heat Source) (CH50 and DM8 used in Tandem)
•The triple position AC element switch controls the activation of a single 120 VAC immersion element only, dual 120 VAC immersion elements jointly, or both elements off. The AC heat LED will turn ON to indicate when the element(s) have been activated.
Engine
Preheating the Engine
•The engine
Burner LED (Green)
•When ON, indicates the diesel burner has been activated.
AC Heat LED (Green)
•When ON, indicates the 120 VAC immersion elements(s) are activated.
Module Fault LED (Red)
•When ON, indicates the Oasis™ Heating Module has faulted. The specific fault can be identified by examining the Oasis™ Heating Module Control Panel located on the front of the Oasis™ Heating Module. There are indicator LED’s on the panel that are used for diagnostics. Refer to the description of the Oasis™ Heating Module Control Panel for further details.
Zone Fault LED (Red) (Functional with Distribution Module Equipped Models Only )
The Oasis™ Heating Module |