Installing the Distribution Module, DM12

Thank you for purchasing the Distribution Module, DM12.

This section describes its installation.

9.1Installing your Distribution Module Equipment, Tools and Skills

NOTICE

As the Installer, you must be qualified and authorized to do the installation which requires mechanical and electrical knowledge.

The module is to be installed in accordance with the standards and regulations of authorities having jurisdiction. Proper workmanship is essential to the proper function and life of your module as well as protecting your warranty.

9.2 Selecting the Module Location

The installation should consider the following:

Mounting location must be able to support double the gross weight of the Distribution Module (i.e. 33 lbs. x 2 = 66 lbs./13 KG x 2 = 26 KG) and must be of a non-combustible and non absorptive surface.

The module must be mounted in an area that provides unrestricted access to the front panel (minimum of 6” top clearance) with 3” clearance to all other module surfaces.

Module is 11”H x 14”W x 6.5” D. (27.9cm x 35.5cm x 15.2cm). See Figure 9-1: Distribution Module, DM12.