Section 8, Operating the Heating Module

When ON, indicates the space heating zone(s) has faulted. The specific fault can be identified by examining the Distribution Module Zone Control Panel (optional) located beside the Oasis™ Heating Module. There are indicator LED’s on the panel that indicate the problem. Refer to the description of the Distribution Module Zone Control Panel for further details.

8.10Functions of the Heating Module Control Panel

The Oasis™ Heating Module’s Control Panel, Figure 8-2: Heating Module Main Control Panel, contains three push buttons: ON/OFF power, Bypass, and Reset. In addition, it contains nine LED’s indicating Power, AC Heat, Compressor, Fuel Pump, Combustion Fan, Igniter, Flame Out, Voltage and Low Water.

Power Button

The power button turns ON/OFF the power to the control board. The Power LED (green) turns ON when the power to the control board is ON.

Bypass ButtonThe bypass button is for authorized service personnel only.Reset Button

The reset button when pressed resets the control board.

Power LED (Green)

The power LED (green) turns ON when the power to the control board is ON. The LED flashes when the Oasis™ Heating Module is in Bypass mode.

AC Heat LED (Green)

The AC Heat LED (Green) turns ON when a single or dual AC immersion element(s) have been activated.

International Thermal Research

8-9