Section

3

Installing the Exhaust System

3.1 Before You Begin

!DANGER

For efficient and safe operation of the Oasis™ Heating Module follow all recommendations for properly installing the exhaust. Any deviations from these must be approved in advance by ITR.

Although the heater’s exhaust produces very low carbon monoxide emissions, caution is still advised:

Do not operate the Oasis™ Heating Module in an enclosed area unless there is adequate ventilation.

Isolate the Oasis™ Heating Module in a closed compartment so that no air from the unit will infiltrate the living areas.

Never place any exhaust parts close to combustible material or through a combustible wall or ceiling without fireproof protection. The exhaust can reach high temperatures.

3.2Mounting Location

If you can’t meet the technical specifications for mounting the exhaust, don’t use the Oasis™ Heating Module. The unit may perform poorly or become damaged if not installed according to specifications.

Recommended Exhaust Outlet Locations

The following is recommended for a coach exhaust outlet location:

Mount the exhaust outlet outside the coach, not inside the heater compartment. Otherwise, exhaust fumes could infiltrate the coach from the Oasis™ Heating Module.

International Thermal Research

3-1