Section 8, Operating the Heating Module
•Oasis™ Heating Module connected to 12 VDC power?
•Power button on Oasis™ Heating Module Control Panel pushed ON? Power LED lit on Oasis™ Heating Module Control Panel?
•Burner switch on Remote Operating Panel ON? Burner LED lit on Remote Operating Panel?
•Main fuse or circuit breaker blown or tripped?
AC immersion elements do not activate•Module connected to 120 VAC power?
•AC switch on Remote Operating Panel placed in the one or two element position? AC Heat LED lit on Remote Operating Panel?
•AC immersion elements circuit breakers tripped?
Burner Starts but Flame Faults•Fuel supply present and adequate?
•
•Air in fuel line (white smoke from exhaust or popping sound from exhaust)?
•Fuel filter (external) dirty?
•Restrict the fuel return line with needle valve or pinch off completely.
Burner Starts but Zone Faults•Power LED on Distribution Module Zone Control Panel glowing green?
•Component matched LED pairings all glowing green on the Distribution Module Zone Control Panel?