Panasonic AJ-LT85P Error Messages, Error No, Details of error, VTR operation, Forced POWER OFF

Models: AJ-LT85P

1 76
Download 76 pages 10.73 Kb
Page 70
Image 70
Forced POWER OFF (*)

ERROR MESSAGES

Error No.

Details of error

VTR operation

 

 

 

E-64

The take-up reel motor speed is abnormally high.

STOP

 

 

 

E-65

Abnormal tension has been detected.

STOP

 

 

 

E-66

At the tape start or end, the short FF or REW operation does not stop even after 7

STOP

 

or more seconds.

 

 

 

 

E-67

A check sum error was detected in the serial data communication between the

STOP

 

syscon and servo.

 

 

 

 

E-68

In serial data communication between the syscon and servo, the data was fixed at

STOP

 

low or high and the absence of data was detected.

 

 

 

 

E-69

A communication error was detected in the serial data between the syscon and

STOP

 

servo when the power was turned on.

 

 

 

 

E-70

About an hour has elapsed after the fan motor stopped. The VTR forcibly turns off

Forced POWER OFF

 

its power.

 

 

 

 

E-71

The heat sensor was activated and an abnormally high temperature inside the

Forced POWER OFF

 

VTR was detected.

 

 

 

 

E-72

Trouble in the solenoid drive circuitry was detected.

Forced POWER OFF

 

 

 

E-73

Trouble in the cleaning solenoid drive circuitry was detected.

Forced POWER OFF

 

 

 

E-BA

The input supply voltage dropped below the undercut voltage.

Forced POWER OFF (*)

 

 

 

(*) The counter display flashes to provide a warning.

70

Page 70
Image 70
Panasonic AJ-LT85P manual Error Messages, Error No, Details of error, VTR operation, Forced POWER OFF