TIME CODES (TC) and USER BITS (UB)
REC SAME function
This function is used to record the same time code and user bit values on VTR1 and VTR2 when both machines are in the record (NORMAL REC) mode. The values from the time code generator (TCG) and user bit generator (UBG) are recorded on both VTR1 and VTR2.
Turning on the REC SAME function
!Set the VTR to the stop mode. @ Switch to the
# Set VTR2 item No. 507 to VTR1TC (0004).
$ Set the OPERATION MODE switch on the front keyboard to SEP.
<Note>
The REC SAME function causes the time codes and user bits recorded on VTR1 and VTR2 to match only while both are in the record (NORMAL REC) mode. Therefore, if VTR1 is not in the record (NORMAL REC) mode, the time codes recorded on the VTR2 may lack continuity. The same user bit values continue to be recorded. Also, VTR2 always uses the TCG and UBG of VTR1 for regeneration, regardless of the setting for item No. 507 (TC MODE).
REC THROUGH function
When a multiple number of VTRs have been connected in a
<Note>
In the case of the master VTR, set the TC OUT output timing to TCOUT1 irrespective of the TC MODE.
In the case of the slave VTRs, set the TC OUT output timing to TCOUT1 when
VITC output specifications
Mode | VTR1 (V MONI) | VTR2 (V MONI, V OUT) | |
|
|
| |
VV system | Data on the tape | Data on the tape | |
|
|
| |
During TC | Data input | TC recording data | |
recording | externally | ||
| |||
|
|
| |
| Data input | Data input externally | |
EE system | (At INT setting: internal | ||
externally | |||
| data from VTR1) | ||
|
| ||
|
|
|
<Note>
The item No.502 (VITC BLANK) setting of VTR1 is valid only during playback.
In any other mode, the data which is input from an external source will be output.
TC OUT (LTC) output specifications
Playback system | : The data on the tape is output at the TCOUT2 timing. |
| |||||
All other systems : Refer to the table below. |
|
| |||||
|
|
|
|
|
|
|
|
TC MODE |
| Output data |
| <Remarks> |
| ||
| Output timing | TCG | :Time code generator value� | ||||
(see actual modes |
| source | |||||
| Menu item | VITCR | : External VITC input data | ||||
of TCG/UBG on |
|
|
|
| |||
|
|
|
| No.513 setting | LTCR | : External LTC input data� | |
page 61) |
| VTR1 |
| VTR2 | |||
|
|
| VTR1 TCR : Data on VTR1 tape | ||||
|
|
|
|
|
| ||
|
|
| TCG | TCOUT1/TCOUT2 | REC THROUGH function enabled (during TC recording) | ||
|
| TCG | TCOUT1/TCOUT2 | REC THROUGH function enabled | |||
| Data on tape | TCOUT1/TCOUT2 | REC THROUGH function enabled (during TC recording) (VTR2, TCOUT2) | ||||
|
| TCG |
| VITCR | TCOUT1/TCOUT2 | REC THROUGH function enabled (during VITC input on which | |
|
|
|
|
|
| continuous TC values are superimposed) | |
| LTCR | TCOUT1/TCOUT2 | REC THROUGH function enabled (during LTC input on which | ||||
|
|
|
|
|
| continuous TC values are superimposed) | |
VTR1TC(VTR2) |
| — |
| VTR1 | TCOUT1/TCOUT2 | REC THOROUGH function enabled (during playback of tape | |
|
|
|
| TCR |
| on which VTR1 has recorded continuous TC values) | |
VTR1TCG(VTR2) |
| — |
| TCG | TCOUT1/TCOUT2 | REC THROUGH function enabled (when the TCG values of | |
|
|
|
|
|
| VTR1 are continuous) |
62