TIME CODES (TC) and USER BITS (UB)

REC SAME function

This function is used to record the same time code and user bit values on VTR1 and VTR2 when both machines are in the record (NORMAL REC) mode. The values from the time code generator (TCG) and user bit generator (UBG) are recorded on both VTR1 and VTR2.

Turning on the REC SAME function

!Set the VTR to the stop mode. @ Switch to the set-up menu.

# Set VTR2 item No. 507 to VTR1TC (0004).

$ Set the OPERATION MODE switch on the front keyboard to SEP.

<Note>

The REC SAME function causes the time codes and user bits recorded on VTR1 and VTR2 to match only while both are in the record (NORMAL REC) mode. Therefore, if VTR1 is not in the record (NORMAL REC) mode, the time codes recorded on the VTR2 may lack continuity. The same user bit values continue to be recorded. Also, VTR2 always uses the TCG and UBG of VTR1 for regeneration, regardless of the setting for item No. 507 (TC MODE).

REC THROUGH function

When a multiple number of VTRs have been connected in a daisy-chain configuration using TC IN/OUT (LTC), this function enables recording by using TC IN/OUT (LTC) so that the master VTR’s time code generator value will serve as the reference TC for all the VTRs.

<Note>

In the case of the master VTR, set the TC OUT output timing to TCOUT1 irrespective of the TC MODE.

In the case of the slave VTRs, set the TC OUT output timing to TCOUT1 when E-LTC is selected as the TC MODE.

VITC output specifications

Mode

VTR1 (V MONI)

VTR2 (V MONI, V OUT)

 

 

 

VV system

Data on the tape

Data on the tape

 

 

 

During TC

Data input

TC recording data

recording

externally

 

 

 

 

 

Data input

Data input externally

EE system

(At INT setting: internal

externally

 

data from VTR1)

 

 

 

 

 

<Note>

The item No.502 (VITC BLANK) setting of VTR1 is valid only during playback.

In any other mode, the data which is input from an external source will be output.

TC OUT (LTC) output specifications

Playback system

: The data on the tape is output at the TCOUT2 timing.

 

All other systems : Refer to the table below.

 

 

 

 

 

 

 

 

 

 

TC MODE

 

Output data

 

<Remarks>

 

 

Output timing

TCG

:Time code generator value

(see actual modes

 

source

 

Menu item

VITCR

: External VITC input data

of TCG/UBG on

 

 

 

 

 

 

 

 

No.513 setting

LTCR

: External LTC input data

page 61)

 

VTR1

 

VTR2

 

 

 

VTR1 TCR : Data on VTR1 tape

 

 

 

 

 

 

P-REC

 

 

TCG

TCOUT1/TCOUT2

REC THROUGH function enabled (during TC recording)

P-FREE

 

 

TCG

TCOUT1/TCOUT2

REC THROUGH function enabled

I-REG

 

Data on tape

TCOUT1/TCOUT2

REC THROUGH function enabled (during TC recording) (VTR2, TCOUT2)

E-VITC

 

TCG

 

VITCR

TCOUT1/TCOUT2

REC THROUGH function enabled (during VITC input on which

 

 

 

 

 

 

continuous TC values are superimposed)

E-LTC

 

LTCR

TCOUT1/TCOUT2

REC THROUGH function enabled (during LTC input on which

 

 

 

 

 

 

continuous TC values are superimposed)

VTR1TC(VTR2)

 

 

VTR1

TCOUT1/TCOUT2

REC THOROUGH function enabled (during playback of tape

 

 

 

 

TCR

 

on which VTR1 has recorded continuous TC values)

VTR1TCG(VTR2)

 

 

TCG

TCOUT1/TCOUT2

REC THROUGH function enabled (when the TCG values of

 

 

 

 

 

 

VTR1 are continuous)

62

Page 62
Image 62
Panasonic AJ-LT85P manual Turning on the REC Same function, REC Through function, Vitc output specifications