DETAILED DESCRIPTION OF DIAG MENU

DETAILED DESCRIPTION OF DIAG MENU

Details of the hour meter display are given below.

 

Item

Data

Description

 

 

 

No.

Display

Display

 

 

 

 

 

H00

OPERATION

00000H

The period of time during which the power has been supplied since it

 

 

 

was turned on is displayed in 1-hour increments.

 

 

999999H

 

 

 

 

 

H01

DRUM RUN

00000H

The period of time during which the drum has been rotating is displayed

 

 

 

in 1-hour increments.

 

 

999999H

 

 

 

 

 

H02

TAPE RUN

00000H

The tape travel duration in the fast forward, rewind, play, search (JOG,

 

 

 

VAR, SHTL), recording or editing mode (but not in the STILL mode with

 

 

999999H

JOG, VAR and SHTL) is displayed in 1-hour increments.

 

 

 

 

 

 

 

H03

THREADING

00000H

The number of times the tape has been threaded or unthreaded is

 

 

 

didplayed in 1-time increments.

 

 

999999H

 

 

 

 

 

The H11 to H13 numbers are displays which are used by the servicing technicians.