Black level (master pedestal) adjustment (continued)

When performing the operations using the controller

When the AWRP655 is connected:

1Press the [IRIS] button several times to turn off its lamp.

Set the iris to the manual ([MANU]) mode.

2Turn the [FOCUS/IRIS] dial to stop down the lens iris.

3Press the [R/B GAIN/PED] button several times so that the “PEDESTAL TOTAL” item is displayed on the LCD panel.

4Turn the jog dial (main) and adjust the black level to 0.035 V.

5If necessary, adjust the iris automatically.

Press the [IRIS] button several times to turn on its lamp.

When the AWRP555 is connected:

1Press the [IRIS] button several times to turn off its lamp.

Set the iris to the manual ([MANU]) mode.

2Turn the [LEVEL] dial of [IRIS] to stop down the lens iris.

3Follow the operation steps in “Basic operations” (page 38), and use the camera menu to perform the adjustment.

When the AWRP50 is connected:

Refer to the Operating Instructions of the controller.

28

Page 28
Image 28