Chapter 4
The following
=== Panasonic projector report(ERROR) === |
|
|
| |
Projector Type | : RW330 |
|
|
|
Serial No | : SW1234567 |
|
|
|
|
|
| ||
MAIN CPU BUS |
| [ | OK | ] |
FAN |
| [ | OK | ] |
INTAKE AIR TEMPERATURE | [ | OK | ] | |
OPTICS MODULE TEMPERATURE | [ | OK | ] | |
INTERNAL AIR TEMPERATURE | [ | OK | ] | |
LIGHT STATUS |
| [ | OK | ] |
INTAKE AIR TEMP.SENSOR | [ | OK | ] | |
OPTICS MODULE TEMP.SENSOR | [ FAILED ] | |||
INTERNAL AIR TEMP.SENSOR | [ | OK | ] | |
BATTERY |
| [ | OK | ] |
PHOSPHOR WHEEL | [ | OK | ] |
(Error code 00 00 00 00 00 00 00 00 00 00 00 02 00 00 00 00)
Intake air temperature Optics module temperature Internal air temperature
PROJECTOR RUNTIME
:[ | 18 degC / | 64 degF ] |
:[ | 30 degC / | 86 degF ] |
:[ | 28 degC / | 82 degF ] |
9 H |
|
|
MAIN VERSION |
| 1.00 |
NETWORK VERSION | 1.00 | |
SUB VERSION |
| 1.00 |
POWER STATUS |
| POWER=STANDBY |
INPUT SIGNAL |
| |
SIGNAL NAME |
| XGA60 |
SIGNAL FREQUENCY | 48.36kHz / 60.00H | |
DHCP Client | OFF |
|
IP address | 192.168.0.8 | |
MAC address | 04:20:9A:00:00:00 |
Mon Jul 05 14:11:29 2012
[ECO management set up] page
You can make settings for the ECO management function of the projector.
Click [Detailed set up] → [ECO management set up].
1
2
3
4
5
6
7
Select the light source power setting.
2[AUTO POWER SAVE]Select [ON] to set [AMBIENT LIGHT DETECTION], [SIGNAL DETECTION], and [AV MUTE DETECTION].
3[AMBIENT LIGHT DETECTION]Enable ([ON])/disable ([OFF]) the ambient light detection function.
Enable ([ON])/disable ([OFF]) the signal detection function.
5[AV MUTE DETECTION]Enable ([ON])/disable ([OFF]) the AV mute detection function.
6[NO SIGNALSelect the time until the projector enters the standby mode when the signal detection function is used.
7[Submit]Update the setting.