Chapter 5  Maintenance — Light source/temperature indicator

Temperature indicator <TEMP>

Indicator status

Lighting in red

Flashing in red

Flashing in red

Flashing in red

(1 time)

(2 time)

(3 time)

 

 

 

Status

 

Internal temperature is

Internal temperature

Internal temperature

 

Warm-up status

is high (during

is high (standby

The fan has stopped.

 

 

high (warning).

projection).

warning).

 

 

 

 

 

 

ff Did you turn on the

ff Is the air intake/exhaust port blocked?

 

 

Cause

power when the

ff Is the room temperature high?

 

 

room temperature

 

 

was low (about 0 °C

 

 

 

 

 

(32 °F))?

 

 

 

 

 

ff Wait at least five

ff Remove any objects that are blocking the air intake/exhaust port.

ff Set the <MAIN

 

minutes in the

ff Set up the projector in a location with an ambient temperature of

POWER>

 

current status.

0 °C (32 °F) to 45 °C (113 °F)*1, and a humidity of 20 % to 80 % (no

switch to <OFF>

 

ff Install the projector

condensation).

 

 

(x page 34), and

Solution

in a location

ff Do not use the projector at high elevations 2 700 m (8 858') or higher

consult your dealer.

 

with an ambient

above sea level.

 

 

 

 

temperature of 0 °C

 

 

 

 

 

(32 °F) to 45 °C

 

 

 

 

 

(113 °F)*1.

 

 

 

 

*1 When using the projector at high altitudes (1 400 m (4 593') – 2 700 m (8 858') above sea level), the ambient temperature will be 0 °C (32 °F) – 40 °C (104 °F).

Note

ff If the temperature indicator <TEMP> is still lit or flashing after taking the preceding measures, ask your dealer to repair the projector.

110 - ENGLISH