Major Operating Controls and Their Functions
15
(1) Handle for Maintenance
Loosen the 5 screws indicated by the triangles and grip these
handles to pull off the panel when replacing the fan or doing
other maintenance work.
(2) Alarm/Control connector [ALARM/
CONTROL], D-Sub 25 pin
Use to connect alarm devices (buzzers or indicators),
external devices, control switches controlled by the recorder.
(3) Alarm connector [ALARM], D-sub 25 pin
Use to connect alarm-related devices such as a sensor or a
door switch.
(4) Cable clamp fixing holes
Install the cable clamp (provided with the extension unit) to
secure the connection cables.
For details refer to the manual for the extension unit (WJ-
HDE400).
(5) External storage connector [EXT STORAGE]
Use to connect the (WJ-HDE400) extension unit and the
recorder with the connection cable (provided with the
extension unit).
(6) Client PC port [PC]
Use to connect a PC, 10BASE-T, 100BASE-TX, or
1000BASE-T network.
(7) Camera port [CAMERA]
Use to connect a camera, 10BASE-T, 100BASE-TX, or
1000BASE-T network.
(8) Signal GND terminal [SIGNAL GND]
Use as a ground when the recorder's Signal GND terminal is
connected to another device's Signal GND terminal. Static or
other noise related problems may occur if a ground is not
connected.
(9) Power cord Inlet [AC IN]
Connect the provided power cord here. The power plug is a
two prong plug with a ground terminal.
(10) Power switch [POWER]
Turns the power on. Press it again to turn the power off and
end operations.
Secure the power cord with the brace.
1Lock the power cord in place by lifting and latching the
brace.

Rear View

(9) (10)(8)(7)(6)(5)
(1)(2) (3) (1)
(4)

Using the Brace

Brace
ND400_Basic.book 15 ページ 2008年7月10日 木曜日 午前10時50分