About Connectors
34

When settings menu - [Basic] - [Time & date] - [Auto adjustment time] is set to [Slave]

[Time Adjust Input] is available and the time on the recorder is synchronized with the other devices.
15 minutes before or after the set [Activation time] if a signal output from another device is input to the Adjustment Time I/O, the time on the
recorder is set to the [Activation time].
Example:
When the [Activation time] is set to 15:00
A signal is received at 2:50:00 pm Set to 3:00:00 pm
A signal is received at 3:14:45 pm Set to 3:00:00 pm
A signal is received at 3:20:00 pm Time is not adjusted.
Connecting alarm equipment like the buzzer and indicator to pins 15 to 18 sounds the buzzer, lights the indicator and indicates operating status
when a signal is output.
An example of HDD error output (pin 16) is shown below.

Auto Adjustment Time Function Connection 2

Important:
When [Auto adjustment time] is set to [Slave], time adjustment is not performed during emergency recording and event recording.

Connectivity for Control Output

2013
(Signal ground)
(Time adjustment input)
ALARM/CONTROL
Front panel
LED monitor
output
Series recording output
Time adjustment output
Temperature warning output
System error output
Buzzer output
Disk
Recording
Alarm recording
Alarm restore output
Alarm output
Signal ground
Time adjustment input
Series recording input
Alarm reset input
Alarm Input
Sensor input
Signal ground

Terminal for other devices

1613
(HDD error output)
(Signal ground)
Alarm equipment
ALARM/CONTROL *Attached when necessary.
Relays etc.*
ND400_Basic.book 34 ページ 2008年7月10日 木曜日 午前10時50分