Paradyne JetFusion Integrated Access Device Setting Slic Con- trol Mode, Setting Com- pander Mode

Models: JetFusion Integrated Access Device

1 297
Download 297 pages 52.68 Kb
Page 151
Image 151

Setting SLIC Con- trol Mode

To set SLIC control mode (for POTS only), type T to display the SLIC Control Mode Selection menu:

Figure 7–5. SLIC Control Mode Selection Menu

*******************************************

SLIC Control Mode Selection

*******************************************

Current Control Mode = AUTO Control Mode

A. AUTO Control Mode

B. MANUAL Control Mode

Type the option of the control mode to set.

1.The IAD saves the mode you’ve selected and displays the menu.

2.Press Escape to return to the Voice Configuration menu and continue with other voice path configuration.

3.Reset the IAD (page 14) when you finish voice path configuration.

NOTE Voice gateway applications, such as CopperCom or JetStream, overrides the value set by this command.

Setting Com- pander Mode

To set Compander Mode, type U to display the Compander Mode Selection menu:

Figure 7–6. Start Mode Selection Menu

*******************************************

Compander Mode Selection

*******************************************

Current Compander Mode = u-Law

U.u-Law Mode A. A-Law Mode

1.Type the option of the Compander mode to set.

2.The IAD saves the mode you’ve selected and displays the menu.

3.Press Escape to return to the Voice Configuration menu and continue with other voice path configuration.

4.Reset the IAD (page 14) when you finish voice path configuration.

NOTE If you are unsure which mode to use, check with your telephone service provider. Normally, u-Law is used in North America and a-Law is used in Europe.

2000-A2-GB20-10

- 132 -

February 2004

Page 151
Image 151
Paradyne JetFusion Integrated Access Device manual Setting Slic Con- trol Mode, Setting Com- pander Mode