Paradyne JetFusion Integrated Access Device manual Configuring S-Bits, 31. E1 Configuration menu

Models: JetFusion Integrated Access Device

1 297
Download 297 pages 52.68 Kb
Page 91
Image 91

Figure 4–31. E1 Configuration menu

*******************************************

Select E1 Frame Mode

*******************************************

E1 Frame Mode

= FAS

1.FAS

2.FAS (CRC4 Enabled)

3.Multi-Frame CAS

4.Multi-Frame CAS (CRC4 Enabled)

Type the option to set the frame mode.

2.The IAD saves the configuration, resets the interface and displays the menu. (The menu and reset messages may conflict—press any key to refresh the menu.)

3.Press Escape to return to the E1 Configuration menu and continue with other configuration tasks.

4.Reset the IAD (page 14) when you finish E1 configuration.

Setting Line Build Out

1.Type 3 (Select Transmit Line Build Out) to display the Line Build Out menu.

Figure 4–32. Select Line Build Out Menu

**********************************

Select Line Build Out

**********************************

Line Build Out Is 0 dB

1.0 dB

2.-7.5 dB

3.-15 dB

4.-22.5 dB

Type the option to select the line build out decibel setting.

2.The IAD resets the interface and displays the menu.

3.Press Escape to return to the E1 Configuration menu and continue with other configuration tasks.

4.Reset the IAD (page 14) when you finish E1 configuration.

Configuring S-Bits

The E1 Configuration menu displays.

1.Type 4 to select Configure S-Bits.

2.The IAD displays the Configure S-Bits menu and current settings.

2000-A2-GB20-10

- 72 -

February 2004

Page 91
Image 91
Paradyne JetFusion Integrated Access Device manual Configuring S-Bits, 31. E1 Configuration menu