Chapter 8, Firewall Configuration on page 154, provides information about setting up the IAD to perform IP filtering.

Chapter 9, DHCP Server Configuration on page 155, walks you through the steps required to configure the Dynamic Host Configuration Protocol (DHCP) server and client.

Chapter 10, Multicast Configuration on page 163, describes the steps to configure the IAD to perform Network Address Translation (NAT).

Chapter 11, NAT Configuration on page 169, describes the steps required to configure the IAD to perform Network Address Translation (NAT).

Chapter 12, IAD Reports on page 181, describes each report you can run.

Chapter 13, Command Line Interface on page 221, describes how to enter and exit CLI mode, and how to use each command in the command line interface. You may use these commands instead of using the corresponding commands in the menu interface.

Chapter 14, Troubleshooting and Diagnostics on page 236, shows you how to troubleshoot and diagnose your IAD configuration when abnormal symptoms occur in the voice or computer network.

Chapter 15, Verification on page 247, describes the steps you take to verify normal operation once you’ve installed, connected and configured the IAD. It also covers maintenance and how to display the current configuration.

Appendix A, Menu Map on page 250, provides a graphic view of the IAD menu interface, illustrating its navigation and organization.

Appendix B, Country Codes on page 252, lists the specifications for each country code supported in the IAD.

Appendix C, JetFusion IAD Specifications on page 254, lists the specifications for each IAD.

Appendix D, Connector Pinouts on page 265, provides interface pinout information for each type of port on the IADs.

Safeguards You should read and understand the following precautions and warnings before using the JetFusion IAD. You should post these precautions in a clearly visible location near each IAD.

￿The Safety status of the SLIC ports on this product are defined as TNV -2. Therefore, cables attached to them should not be subject to over voltage. To ensure this they should not leave the building in which the Unit is installed.

￿Close supervision is necessary when the system is used by or near children. Do not leave unattended while in use.

￿Only use electrical extension cords with a current rating equal to that of the system.

￿Always disconnect the system from power before cleaning and servicing and when not in use.

￿Do not spray liquids directly onto the system when cleaning. Always apply the liquid first to a static free cloth.

￿Do not immerse the system in any liquid or place any liquids on it.