Enabling or Disabling Specific Channels

1.Type 3 to enable or disable specific channels. If all channels are disabled, this option enables specific channels. Conversely, if all channels are enabled, this option disables specific channels.

2.The IAD displays this prompt:

Select Channel to Enable/Disable, then press Enter.

3.For each channel, type the number and press Enter. When you have entered all channels to enable or disable, press Enter.

4.The IAD makes the change and saves the configuration and displays the E1 Configuration menu.

5.Continue with other configuration tasks.

6.Reset the IAD (page 14) when you finish E1 configuration.

Selecting a Channel Range

1.Type 4 to enable a range of channels.

2.The IAD displays the channel status and a prompt:

Tx Channels Enabled = No Channels Enabled.

Select a Channel Range to Enable (Available Range: 1 to 24).

First Channel of Range ->

Type the beginning channel and press Enter.

3.The IAD displays the second prompt:

Last Channel of Range ->

Type the ending channel to enable and press Enter.

4.The IAD makes the change and saves the configuration and displays the E1 Configuration menu.

5.Continue with other configuration tasks.

6.Reset the IAD (page 14) when you finish E1 configuration.

Configuring the Transmit Clock Source

1.Type 8 to select Configure Transmit Clock Source and display the Select Tx Clock Source menu and status message.

Figure 4–35. Select Tx Clock Source menu

**********************************

Select Tx Clock Source

**********************************

Tx Clock is derived from Rx clock (Slave Mode).

1.External (Slave Mode)

2.Internal (Master Mode)

Type 1 to select external or type 2 to select Internal mode.

2.The IAD saves the configuration and resets the interface.

3.Press Escape to return to the E1 Configuration menu and continue with other configuration tasks.

4.Reset the IAD (page 14) when you finish E1 configuration.

2000-A2-GB20-10

- 74 -

February 2004

Page 93
Image 93
Paradyne JetFusion Integrated Access Device manual Configuring the Transmit Clock Source, Select Tx Clock Source menu

JetFusion Integrated Access Device specifications

The Paradyne JetFusion Integrated Access Device represents a significant advancement in network access technology, designed to meet the growing demand for high-performance connectivity in both residential and business environments. This device seamlessly integrates multiple access technologies into a single platform, offering enhanced flexibility, efficiency, and scalability.

One of the standout features of the JetFusion is its capability to support a variety of broadband access methods, including DSL, fiber optics, and cable. This multi-access functionality allows service providers to optimize their networks by deploying the most effective technology based on the specific needs of their customers. The device intelligently manages these connections, ensuring that users experience consistent and reliable internet service.

The JetFusion is equipped with advanced Quality of Service (QoS) mechanisms, enabling it to prioritize traffic based on user requirements and application demands. This is particularly important in environments where bandwidth-intensive applications, such as video streaming and online gaming, are prevalent. With built-in QoS, the JetFusion ensures that critical applications receive the necessary bandwidth while maintaining overall network performance.

Another impressive characteristic of the JetFusion is its support for IPv6, which is increasingly vital as more devices connect to the internet. The device's compatibility with this next-generation protocol allows for a greater number of unique IP addresses, facilitating the growth of smart homes and IoT applications.

The JetFusion also integrates security features to protect sensitive data and maintain privacy. With robust encryption and firewall capabilities, the device provides a secure gateway for both home and office networks. This aspect is crucial in today’s digital landscape, where cyber threats are a significant concern.

Moreover, the device includes remote management capabilities. Network operators can monitor and manage the JetFusion through a centralized platform, leading to improved operational efficiency and faster troubleshooting. This level of control is essential for maintaining high service levels and ensuring customer satisfaction.

In conclusion, the Paradyne JetFusion Integrated Access Device stands out for its multi-access support, advanced QoS mechanisms, IPv6 compatibility, security features, and remote management capabilities. These characteristics make it an ideal solution for service providers aiming to deliver reliable, high-performance internet access to a diverse range of users. As demand for broadband connectivity continues to surge, the JetFusion is poised to play a pivotal role in the evolution of network access technology.