C o n f i g u r i n g t h e P a r t n e r P r i n t e r
The partner printer must be configured to 115200 Baud, No parity,
1.Select Setup, Port Settings, Serial Comm from the partner printer’s Main Menu. If password protection in enabled, press Feed/Cut three times, then press Enter/Pause before you see the Setup Menu options.
2. | Select Baud Rate and press | or | to scroll until you see | ||
| 115200. Press Enter/Pause. |
|
| ||
3. | Press | or | to select Word Length. Scroll until you see 8. | ||
| Press Enter/Pause. |
|
| ||
4. | Press | or | to select Stop Bits. | Scroll until you see 1. | |
| Press Enter/Pause. |
|
| ||
5. | Press | or | to select Parity. | Scroll until you see None. | |
| Press Enter/Pause. |
|
| ||
6. | Press | or | to select Flow Control. Scroll until you see XON- | ||
| XOFF. | Press Enter/Pause. |
|
|
U s i n g t h e S m a r t R e l a y T e l n e t C o m m a n d s
See the following list of commands to configure the printers.
SET PRN RELay PORt [None/S2]
Sets the Smart Relay Partner Identification (port) number to None (no partner printer) or S2 (partner printer connected to serial port 2). The default is None.
Using the Smart Relay System