SET PRN RELay FILter [OFF/NONE/RFID/NONRFID]
Sets the Smart Relay Filter to
OFF | Does not forward any data - primary printer prints all |
| batches. |
NONE | Forwards ALL data to primary AND partner printer – batches |
| print on both the primary and partner printers. |
RFID | Forwards RFID batches to the partner printer. |
| Forwards |
The default is None.
Setting the Smart Relay Filter to None causes the batch to print on BOTH the primary and partner printers. To use this option, you may need a custom script (application) to perform additional filtering. For example, a custom application filters which format is printed between two printers loaded with
SET PRN RELay COUNTer [NONE0-9999]
Sets the Smart Relay Counter Number to None (no counter is used) or 0 to 9999 (beginning value for counter). The default is None.
SET PRN RELay POS [0-2400] [0-2400]
Sets the Smart Relay Field position (collation field) in graphic dot row and column values. The default is 0,0.
The CLear and SHow commands can also be used on these commands. Using CLear sets the values back to their defaults.
Example SET PRN REL POR S2
Sets the Smart Relay port to serial port 2 (enables the Smart Relay system).
Note: After sending this command, turn off the printer. Wait several seconds and then turn on the printer for the command to take effect.
Example SET PRN REL FIL NONRFID
Sets the Smart Relay filter to