Table AI. Motion-Activated Relay Settings

 

 

Option

Result

 

 

Disable

Relay will not activate when motion is detected.

 

 

Follow Event

Relay will activate at the exact moment that motion is detected.

 

 

1, 3, 5, 10,15, and 20 Seconds

Sets the amount of time the relay will remain active after motion has been detected.

 

 

Configuring Advanced Alarm-Activated Relay Output

To configure an alarm relay output:

1. On the DX8100 toolbar, click . The Setup dialog box opens to the Camera page.

2. In the Setup dialog box, click

. The Schedule page is displayed.

3.Click the Configure Relays button. The Configure Relays dialog box opens.

4.Click the Alarm tab if it is not already selected.

5.Configure each relay that is linked to an alarm:

a.Click the drop-down box to select a relay.

b.Select a relay time value from the Activation Period drop-down box.

￿5a

5b

Figure 131. Linking Relays to Alarms

The following table describes the available options.

 

Table AJ. Alarm-Activated Relay Settings

 

 

Option

Result

 

 

Disable

Relay will not activate when the alarm is triggered.

 

 

Follow Event

Relay will activate at the exact moment the alarm is triggered.

 

 

1, 3, 5, 10,15, and 20 Seconds

Sets the amount of time the relay will remain active after the alarm has been triggered.

 

 

148

Client Application

C2631M-A (6/07)

Page 148
Image 148