Pelco ES30TI manual Green wire

Models: ES30TI

1 60
Download 60 pages 63.45 Kb
Page 10
Image 10
Manual background

c.Connect the wiring for a 2-wire or 4-wire control system. This step does not apply to Coaxitron® control systems.

Green wire

RX-

 

 

Red wire

RX+

 

 

Black wire

TX-

 

 

White wire

TX+

 

 

d.Connect AUX 2 (optional). Refer to the schematic drawing for an example of how to wire AUX 2.

Orange wire

AUX 2

 

 

Blue wire

AUX 2 COMMON

 

 

USER

ESPRITACCESSORY

K1

OMRON G5V-1-DC12

D1

1N4005

AUX 2

AUX 2

ORANGE WIRE

 

AUX 2 COM

AUX 2 COM

BLUE WIRE

 

V1

32 VDC

NOTE: CURRENT MUST NOT EXCEED 40 mA.

Figure 5. AUX 2 Schematic Drawing

7.Install mount; refer to the installation manual supplied with the mount for instructions.

8.Turn on system power. If the red LED glows, turn off the power and proceed to the next step. If the red LED does not glow, refer to Maintenance and Troubleshooting on page 52.