Pelco ES30TI manual Flat Field Correction Ffc, Frequency

Models: ES30TI

1 60
Download 60 pages 63.45 Kb
Page 29
Image 29
FLAT FIELD CORRECTION (FFC)

FLAT FIELD CORRECTION (FFC)

MAIN MENU

 

 

Camera Menu

 

Flat Field Correction Menu

 

 

 

 

Display Type

White Hot

 

 

 

<Camera>

 

 

 

Frequency <min>

2

<Power Up Mode>

 

 

Profile

Night

 

Temp Change <C>

1.0

<Limit Stops>

 

 

<Sharp/Contrast/Bias>

 

Do Manual FFC

 

<Other>

 

 

 

Exit

 

<System Information>

 

 

<Region of Interest>

 

 

 

<Factory Defaults>

 

 

<Flat Field Correction>

 

 

 

 

Exit

 

 

Exit

 

 

 

 

 

Flat Field Correction (FFC) controls how the camera regularly adjusts its thermal settings to optimize its image. This process takes about 0.5 seconds. During this process, there may be a lag in image quality.

Before performing the FFC process, the camera warns the operator by displaying a small blinking box in the upper left corner. This indicator appears for 2 seconds.

You can delay the FFC process at any time. Press the Iris Close button to delay the FFC for at least one minute. Use the delay option when you are observing activity that would be interrupted by the FFC process.

The following sections describe how to use each FFC option.

FREQUENCY

Frequency controls how often the camera performs the FFC process, regardless of the temperature change in the field of view. After each FFC, the camera restarts the frequency clock.

You can select from 2 to 16 minutes. The default is 2 minutes.

NOTE: For best results, keep the Frequency setting at the default value.

To program the frequency:

1.Program preset 95 (28). The main menu appears.

2.Position the cursor (>) beside <Camera>. Press the Iris Open button; the menu appears.

3.Position the cursor (>) beside <Flat Field Correction>. Press the Iris Open button; the menu appears.

4.Position the cursor (>) beside Frequency <min>. Press the Iris Open button; the cursor moves to the right.

5.Move the joystick up or down until the desired Frequency setting appears.

6.Do one of the following:

Select: Press the Iris Open button to select the option.

Cancel: Press the Iris Close button to leave the setting as is.

C1307M-C (8/07)

29

Page 29
Image 29
Pelco ES30TI manual Flat Field Correction Ffc, Frequency