Pelco ES30TI manual Display Duration

Models: ES30TI

1 60
Download 60 pages 63.45 Kb
Page 27
Image 27
DISPLAY DURATION

DISPLAY DURATION

MAIN MENU

 

 

Other Menu

 

 

 

 

Az/El/Direction

 

<Camera>

 

 

Temp Units

 

Celsius

 

 

Set Azimuth Zero

 

<Power Up Mode>

 

 

Park time minutes

0

 

 

 

Az/El

Left

<Limit Stops>

 

 

Scan Speed deg/s

7

 

 

 

Az/El Line

10

<Other>

 

 

 

Pattern Length

 

1.5 min

 

 

Direction

Right

<System Information>

 

 

Spd Profile

90 MPH Wind

 

 

Direction Line

10

<Factory Defaults>

 

 

<Zone Blank>

 

 

 

 

 

Zoom

Center

Exit

 

 

<Az/El/Direction>

 

 

 

 

Zoom Line

10

 

 

 

 

 

 

 

 

 

 

 

Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disp Duration

2

Exit

Display Duration programs the duration the Az/El, Direction, and Zoom labels are displayed on the monitor. The available settings for display duration include the following:

Cont: The label appears continuously.

2: The label appears for 2 seconds after PTZ functions end.

5: The label appears for 5 seconds after PTZ functions end.

10: The label appears for 10 seconds after PTZ functions end.

The default is 2 seconds.

To program the display duration for the Az/El, Direction, and Zoom labels:

1.Program preset 95 (28). The main menu appears.

2.Position the cursor (>) beside <Other>. Press the Iris Open button; the menu appears.

3.Position the cursor (>) beside <Az/El/Direction>. Press the Iris Open button; the menu appears.

4.Position the cursor (>) beside Disp Duration. Press the Iris Open button; the cursor moves to the right.

5.Move the joystick up or down to view the available selections.

6.Do one of the following:

Select: Press the Iris Open button to select the option.

Cancel: Press the Iris Close button to leave the setting as is.

C1307M-C (8/07)

27

Page 27
Image 27
Pelco ES30TI manual Display Duration