POWER UP MODE
MAIN MENU | Power Up Mode Menu | |
<Camera> | Power Up | Default |
<Power Up Mode> | Exit |
|
<Limit Stops> <Other>
<System Information> <Factory Defaults> Exit
Use this feature to execute a specific set of commands following the power up sequence. You can select from the following:
•Default: On power up, the system performs a configuration cycle and stops at zero reference, showing Configuration Done, address, and mode settings on the screen.
•Park: The system moves to preset 1 after the configuration cycle ends. The only text on the screen is the preset label (if one is programmed).
•Scan Auto: The system initiates scan mode after the configuration cycle ends.
•Scan Frame: The system initiates a frame scan after the configuration cycle ends.
•Scan Rand: The system initiates a random scan after the configuration cycle ends.
•Full Pat: The system initiates its programmed pattern after the configuration cycle ends. The length can be set to 1.5, 3, or 6 minutes.
•Half Pat 1: The system initiates the first
•Half Pat 2: The system initiates the second
The default setting is Default.
To execute Full Pat, Half Pat 1, or Half Pat 2 upon power up, first program the system with the appropriate pattern.
To select the power up mode:
1.Program preset 95 (28). The main menu appears.
2.Position the cursor (>) beside <Power Up Mode>. Press the Iris Open button; the menu appears.
3.Position the cursor (>) beside Power Up. Press the Iris Open button; the cursor moves to the right.
4.Move the joystick up or down to view the available selections.
5.Do one of the following:
•Select: Press the Iris Open button to select the option.
•Cancel: Press the Iris Close button to leave the setting as is.
37 |