Special installation (Installed facing upward)

[427CMX]

(2) When the Plasma Display is in a confined space

Operating this display in confined spaces is not recommended.

If the display is to be used in confined spaces, observe the following conditions shown in the drawing below: A 50

If heat remains in the enclosed space, the temperature may rise causing a malfunction or fire. As a precaution, the inner wall should have sufficient heat resistance or fire resistance.

Leave a space at least 10 mm wide when installing glass etc. on the front of the Plasma Display.

Usage temperature conditions (*1)

Ambient temperature: 0 °C to 35 °C (Outside air temperature)

Space enclosed by the back surface of the Plasma Display: 0 °C to 35 °C (Use a fan etc. to discharge air to maintain this temperature range.)

*1 For this installation, set the ‘FAN CONTROL’ to ‘MAX’ as shown in “5.4.3 Adjustment and Setting in the Integrator Mode 14) Cooling Fan Control Setting” (pg. 235).

: Thermometer (temperature measurement point)

Outside air temperature measuring point

Outside air

Enclosed space air

temperature

temperature measuring

measuring point

point

 

150 mm

10 mm

 

 

A

 

A 50

50 mm

Enclosed space air temperature measuring point

Note

When installing the Plasma Display facing upwards, do not place anything on top of it nor apply any load on it from

above.