CLOSING THE BASEPLATES

1)Ensure that a cartridge is not inserted in the drive; if it is, unload the cartridge. Remove all cartridges from the shuttle. To remove cartridges from a drive that is not operational, follow the procedure below:

a.)

Ensure that the AC Power switch is set to the OFF ( O ) position.

b.)

At the rear panel, insert the manual release tool into the upper access hole

and engage the recessed D-shaped shaft. Turn the tool handle clockwise as far as it will turn, closing the upper baseplate.

c.) Repeat step b) at the lower manual release access hole to close the lower baseplate.

2)Select the "Park Drive" option, as explained in the Operating Instruction section of this manual.

UPPER

ACCESS

HOLE

MANUAL RELEASE

TOOL

REAR PANEL

LOWER ACCESS

HOLE

EP006047

Manually Closing the Drive's Baseplates

97653976 F Page 29