MANUAL CARTRIDGE RELEASE MECHANISM
If power fails or if the drive fails with a media cartridge inserted, the media cartridge can be manually removed by opening the drive baseplates, removing the bezel and then retracting the cartridge.
OPENING THE BASEPLATES
With the manual release tool, perform the following procedure:
1)Move the AC power switch to the OFF ( O ) position and disconnect the AC power cable from the wall outlet.
2)At the rear panel, insert the manual release tool into the upper access hole and engage the recessed
3)Repeat step 2) at the lower access hole to open the lower baseplate.
UPPER
ACCESS
HOLE
MANUAL
RELEASE TOOL
REAR PANEL
LOWER ACCESS HOLE
EP006046
Manually Opening the LF 6600 Baseplates