TEMPERATURE, HUMIDITY AND ALTITUDE

The following table lists the LF 6600 operating, storage and transit limits for temperature, humidity and altitude.

Temperature, Humidity and Altitude Limits

CONDITION

OPERATING

NONOPERATING

STORAGE/TRANSIT1

Temperature

10 to 42° C 2

-40 to 66° C

-40 to 66° C

 

(50 to 108° F)

-40 to 151° F)

-40 to 151° F)

 

 

 

 

Maximum Rate of

11° C/hr (20° F/hr)

20° C/hr (36° F/hr)

20° C/hr (36° F/hr)

Change

 

 

 

 

 

 

 

Humidity

10 to 99%

5 to 95%

5 to 95%

(Noncondensing

 

 

 

 

 

 

 

Maximum Rate of

10%/hr

10%/hr

10%/hr

Change

 

 

 

 

 

 

 

Maximum Wet Bulb

28° C (82° F)

46° C (115° F)

46° C (115° F)

Temperature 3

 

 

 

 

 

 

 

Minimum Dew Point

2° C (35.6° F)

2° C (35.6°0 F)

2° C (35.6° F)

 

 

 

 

Altitude 4

Storage:

 

Storage:

 

-300 to 3,000 m

-300 to 3,000 m

-300 to 3,000 m

 

(-984 to 9,840 ft)

(0984 to 9840 ft)

(984 to 9,840 ft)

 

Transit:

 

Transit:

 

-300 to 2,000 m

 

-300 to 12,000 m

 

(-984 to 6,562 ft)

 

(-984 to 40,000 ft)

 

with media

 

 

 

 

 

 

1 Storage specifications are for 90 days maximum in Plasmon LMS packaging. No condensation is permitted. Transit specifications are based on a maximum 1-week period in a factory-sealed container.

2Maximum operating temperature is 42 _C for a free-standing drive at sea level unless otherwise stated. Maximum operating temperature is derated linearly above 300 m altitude to 38 _C at 2,000 m altitude.

3See the LD 6100/LF 6600/LF 6602 Product Specification (P/N 97653977) for more information concerning the temperature and humidity operating range.

4Media is limited to 2000 m. For conditions and limits pertaining to the media, refer to the LM 6000 Media Specification (P/N 97647044).