WARNING

The weight of the LF 6600 on the extended platform may cause the equipment cabinet to become unbalanced. Before proceeding, ensure that your cabinet is securely anchored. Do not extend more than one drive at a time.

DO NOT EXTEND MORE

THAN ONE DRIVE AT A

TIME.

IF BOTH DRIVES ARE

EXTENDED AT THE SAME

TIME, THE CABINET MAY

BECOME UMBALANCED.

EP004586

Do Not Extend Both Drives Simultaneously

5)Lower the LF 6600 chassis onto the extended slide platform assembly, seating the three M4 screw heads on the bottom of the chassis into the three locating holes in the slide platform.

WARNING

The LF 6600 must be moved and lifted by two persons. Physical injury can result if one person attempts to move or lift the LF 6600.

Install and tighten three M4 screws horizontally, through the vertical tail of the slide platform to retain the rear of the drive. Install and tighten two M4 screws up into the bottom of chassis to retain the front of the LF 6600.

PLASMON LASER MAGNETIC STORAGE - LF 6600 User Manual Page 42