SETTING THE READ AHEAD OPTION

The read ahead option often improves the overall read data transfer rate of the LF 6600 in applications which require continuous blocks of data to be read (as compared to the same subsystem without read ahead).

Perform the following procedure to turn read ahead on or off.

1)Enter the Configuration mode by pressing both the LOAD/MENU and TEST/SELECT switches simultaneously.

2)Press the MENU switch until "Set Config" is displayed.

3)Press the SELECT switch to enter the Set Configuration menu.

4)Press the MENU switch until "Rd Ahead:" is displayed.

5)Press the SELECT switch to scroll through the states for read ahead (on, off). When the desired state is displayed, press MENU to enter the state and move to the next option in the Set Configuration menu.

6)Simultaneously press the LOAD/MENU and TEST/SELECT switches to exit the Configuration mode. Simultaneously press the LOAD/MENU and TEST/SELECT Switches again to move up to the Main menu.

CAUTION

The read ahead option is system dependent. Ensure that you check with your system analyst before setting this option.

When enabled, the read ahead option uses the data buffer (2 MBytes) to store data sectors read from the disk beyond those sectors requested by the host. Subsequent sequential sectors will be read directly from the buffer instead of incurring the latency time it takes to access sequential sectors. (Refer to the LD 6100/ LF 6600 SCSI Interface Specification [P/N 97653978].)

SETTING THE CDE CURS OPTION

The CDE Curs (Controller Detected Error) option enables a blinking solid cursor in the rightmost character location of the DOC panel when a CDE has occurred. In most system installations, the host system will recover from reported CDE's and no user intervention is required. A developer may wish to enable this indicator during system development or installation.

Perform the following procedure to turn CDE Curs on or off.

1)Enter the Configuration mode by pressing both the LOAD/MENU and TEST/SELECT switches simultaneously.

2)Press the MENU switch until "Set Config" is displayed.

3)Press the SELECT switch to enter the Set Configuration menu.

4)Press the MENU switch until "CDE Curs:" is displayed.

PLASMON LASER MAGNETIC STORAGE - LF 6600 User Manual Page 74

Page 74
Image 74
Plasmon LF6600 user manual Setting the Read Ahead Option, Setting the CDE Curs Option