"Sys Log:" Press the SELECT switch to enable or disable system event logging. The log can be used by a trained CE to help in problem isolation or for performance monitoring. Drive performance will be slowed and may not meet specification if logging is enabled. The default is "Sys Log Off". Press the MENU switch to select the next option in the Diagnostics Menu.
"Test Thru:" Press the SELECT switch to set the level of diagnostics tests which will be performed during selftest (refer to the next table). Selftest is invoked by pressing the TEST switch on the DOC panel.
Tests always start at test 0 and continue through the test number selected by the "Test Thru:" option. For example, if test 5 is selected ("Test Thru:5"), selftest diagnostics will include tests 0 through 5. This selftest series will be performed each time the TEST switch is pressed.
Press the MENU switch to select the next option in the Diagnostics Menu.
| Diagnostics Selftests |
|
|
TEST # | DESCRIPTION OF TEST |
|
|
0 | |
| automatically when the drive is powered on. |
|
|
1 | PCA |
|
|
2 | Read/Write Data Path |
|
|
3 | OMA |
|
|
4 | Cartridge Guide and Shuttle Sensors |
|
|
5 | Baseplate and Spindle Motor Operation |
|
|
6 | Servo Control Systems |
|
|
7 | Read Performance |
|
|
8 | Write Performance, Write Power Calibration |
|
|
9 | Reserved |
|
|
"View RTPM" Press the SELECT switch to view the RTPM (Real Time Performance Monitor) status. If no RTPM error has occurred, the DOC will display "No RTPM Err". If an RTPM error has occurred, the DOC will display the media serial number and drive channel combination which caused the RTPM error. The media serial number will be displayed for 5 sec (S/N: ########) and then the drive channel will be displayed for 4 sec (Channel: A, B, or A+B). The display will then return to the View RTPM option.
PLASMON LASER MAGNETIC STORAGE - LF 6600 User Manual Page 78