IN FROM

HOST

TERMINATOR

EP006061

Single LF 6600 SCSI Interface Cable and Terminator Connection

3)Install a terminator on the vacant connector of the LF 6600.

4)Ensure that the SCSI bus is also terminated at the host adapter end.

5)The SCSI bus must be terminated at both ends in accordance with the LD 6100/LF 6600/ LF 6602 SCSI Interface Specification (P/N 97653978).

CONNECTOR VERIFICATION

Prior to powering on the system:

1)Verify proper termination at the host adapter, if applicable.

2)Verify proper termination at the last LF 6600 on the bus, if applicable.

CAUTION

Ensure that the foam shipping block has been removed from the shuttle assembly before powering on the LF 6600.

Refer to the Operating Instruction section in this manual for power-on procedures.